TEMPORAL AND SPATIAL ASSESSMENT OF INDOOR AIR QUALITY (IAQ) ON PHYSICAL AND CHEMICAL PARAMETERS IN PRIMARY SCHOOLS

Authors

  • Muhamad Hilman Bazli Yahaya Universiti Malaysia Terengganu
  • Amalina Abu Mansor
  • Aimi Nursyahirah Ahmad
  • Samsuri Abdullah Universiti Malaysia Terengganu
  • Zamzam Tuah Ahmad Ramly
  • Mohd Radhie Mohd Salleh
  • Mohammad Fakhratul Ridwan Zulkifli
  • Suriani Mat Jusoh
  • Wan Nurdiyana Wan Mansor
  • Marzuki Ismail

DOI:

https://doi.org/10.46754/umtjur.v5i3.346

Keywords:

air quality, primary school, chemical paramter, physical parameter, spatial mapping

Abstract

Indoor Air Quality (IAQ) is very important for children’s health and well-being since children are particularly vulnerable and sensitive to the presence of air pollutants. Poor Indoor Air Quality brings negative health effects to young children, especially primary school students. The objective of this research was to analyze the chemical and physical parameters inside the classroom at two sites representing institutional and residential area. Spatial mapping was conducted by using Surfer® and Sketchup®. Data were measured using Dust TraxDRX Aerosol 8454, Kanomax IAQ, and TSI IAQ 9545 for three days from 0700 hours to 1400 hours. This research analyzed the chemical and physical parameters inside the classroom, such as particulate matter less than 10 microns (PM10), carbon dioxide (CO2), air temperature, air movement and relative humidity. Results show that the concentration of carbon dioxide (635.5 ppm – 756 ppm) and (723 ppm - 806.5 ppm) for institutional and residential areas are within the limits. The concentration of PM10 was (0.039 mg/m3 – 0.129 mg/m3) and (0.061 mg/m3 – 0.109 mg/m3), relative humidity (76.15% - 88.6%) and (60.9% - 86.75%), air movement (0.08 m/s – 0.82 m/s) and (0.08 m/s – 0.88 m/s) and temperature (27.25˚C – 30.8˚C) and (26.75˚C – 31.0˚C) for institutional and residential area respectively, did not comply with the (ICOP-IAQ 2010) standard. Spatial analysis shows the critical points were at the teacher’s desk, the middle section of the classroom and at the back of the classroom. The critical point was observed in the middle section of the class, as most of the students resided at the back of the classroom where there was furniture that contained particulates.

References

Abdullah, S., Hamid, F. F. A., Ismail, M., Ahmed, A. N., & Mansor, W. N. M. (2019). Data on Indoor Air Quality (IAQ) in kindergartens with different surrounding activities. Data in Brief, 25, 103969.

Department of Occupational Safety and Health, Ministry of Human Resources, Malaysia. (2010). Industrial Code of Practice on Indoor Air Quality 2010 (ICOP IAQ 2010). Putrajaya. Malaysia.

Fu, X., Norbäck, D., Yuan, Q., Li, Y., Zhu, X., Hashim, J., … & Sun, Y. (2021). Association between indoor microbiome exposure and Sick Building Syndrome (SBS) in junior high schools of Johor Bahru, Malaysia. Science of the Total Environment, 753, 141904.

Idris, S. A. A., Hanafiah, M.M., Ismail, M., Abdullah, S., & Khan, M. F. (2020). Laboratory air quality and microbiological contamination in a university building. Arabian Journal of Geosciences, 13, 580.

Jiang, J., Wang, D., Liu, Y., Di, Y., & Liu, J. (2020). A field study of adaptive thermal comfort in primary and secondary school classrooms during winter season in Northwest China. Building and Environment, 175, 106802.

Khalid, W., Zaki, S. A., Rijal, H. B., & Yakub, F. (2018). Investigation of comfort temperature and thermal adaptation for patients and visitors in Malaysian hospitals. Energy and Buildings, 183, 484-499.

Korsavi, S. S., Montazami, A., & Mumovic, D. (2020). The impact of indoor environment quality (IEQ) on school children’s overall comfort in the UK; a regression approach. Building and Environment, 185, 107309.

Lazovic, I. M., Stevanovic, Z. M., Jovasevic- Stojanovic, M. V., Zivkovic, M. M., & Banjac, M. J. (2016). Impact of CO2 concentration on indoor air quality and correlation with relative humidity and indoor air temperature in school buildings in Serbia. Thermal Science, 20, 297-307.

Madureira, J., Paciência, I., Rufo, J., Ramos, E., Barros, H., Teixeira, J. P., & de Oliveira Fernandes, E. (2015). Indoor Air Quality in schools and its relationship with children’s respiratory symptoms. Atmospheric Environment, 118, 145–156.

Mannan, M., & Al-Ghamdi, S. G. (2021). Indoor Air Quality in buildings: A comprehensive review on the factors influencing air pollution in residential and commercial structure. International Journal of Environmental Research and Public Health, 18(6), 3276.

Mansor, A. A., Hisham, A. N. B., Abdullah, S., Napi, N., Ahmed, A. N., & Ismail, M. (2020). Indoor-outdoor Air Quality assessment in nurseries. IOP Conference Series: Earth and Environmental Science, 616, 012001.

Mata, T. M., Martins, A. A., Calheiros, C. S. C., Villanueva, F., Alonso-Cuevilla, N. P., Gabriel, M. F., & Silva, G. V. (2022). Indoor air quality: A review of cleaning technologies. Environments, 9, 118.

Śmiełowska, M., Marć, M., & Zabiegała, B. (2017). Indoor Air Quality in public utility environments—A review. Environmental Science and Pollution Research, 24, 11166– 11176.

Swamy, G. S. N. V. K. S. N. (2021). Development of an indoor air purification system to improve ventilation and air quality. Heliyon, 7(10), e08153.

Tuck, N. W., Zaki, S. A., Hagishima, A., Rijal, H. B., Zakaria, M. A., & Yakub, F. (2019). Effectiveness of free running passive cooling ventilation strategies for indoor thermal environments: Example from a two-storey corner terrace house in Malaysia. Building and Environment, 160, 106214.

Vornanen-Winqvist, C., Järvi, K., Andersson, M. A., Duchaine, C., Létourneau, V., Kedves, O., Kredics, L., Mikkola. R., Kurnitski, J., & Salonen, H. (2020). Exposure to indoor air contaminants in school buildings with and without reported Indoor Air Quality problems. Environment International, 141, 105781.

Wu, Z., Zhang, S., Tang, Y., Jiang, W., Jiang, H., Xie, Z., & Zhang, B. (2020). Indoor environment in relation to recurrent childhood pneumonia in Southern China. Building and Environment, 172, 106727.

Yu, J., Kang, Y., & Zhai, Z. (2020). Advances in research for underground buildings: Energy, thermal comfort and Indoor Air Quality. Energy and Buildings, 215, 109916.

Zubir, N., Jalaludin, J., & Rasdi, I. (2022). Indoor Air Quality and psychosocial factors related to sick building syndrome among office workers in new and old buildings of a public university in Klang Valley, Malaysia. Malaysian Journal of Medicine and Health Sciences, 18, 1-9.

Additional Files

Published

2023-07-18

How to Cite

Yahaya, M. H. B. ., Mansor, A. A., Ahmad, A. N., Abdullah, S., Ramly, Z. T. A., Salleh, M. R. M., Zulkifli, M. F. R. ., Jusoh, S. M., Mansor, W. N. W., & Ismail, M. (2023). TEMPORAL AND SPATIAL ASSESSMENT OF INDOOR AIR QUALITY (IAQ) ON PHYSICAL AND CHEMICAL PARAMETERS IN PRIMARY SCHOOLS . Universiti Malaysia Terengganu Journal of Undergraduate Research, 5(3), 1–8. https://doi.org/10.46754/umtjur.v5i3.346