PARTICULATE RESUSPENSION DURING THE USE OF VACUUM CLEANERS ON OFFICE CARPETS IN UNIVERSITI MALAYSIA TERENGGANU
DOI:
https://doi.org/10.46754/umtjur.v2i2.145Keywords:
Particulate matter, particle resuspension, vacuum cleaners, PM2.5, PM10Abstract
The household activities such as vacuuming may elevate the concentration of
particulate matter in indoor environments. Cleaning workers and occupants inside closed room may be exposed to the fine particulate matter and at risk of developing numerous respiratory symptoms. This study aims to determine the concentration of the particulate matter (PM10 and PM2.5) that might arise during vacuuming activities and estimated the surface compartmental residence time of particulate matter in indoor environment after each vacuuming activities. The PM10 and PM2.5 concentrations throughout vacuuming were measured in forty-seven offices in Universiti Malaysia Terengganu using the TSI Dust Track DRX. Based on the concentrations measured, the surface compartmental residence time was then estimated using standardized equations taken from literature. The result shows that highest particulate matter concentration was nearly eleven times higher than the World Health Organization guidelines of 25 μg/m3 for PM2.5 concentration (PM2.5 was 270μg/m3, PM10 was 421 μg/m3), while the particulate matter were estimated to remain lingers inside the air for around 1-4 days before being deposited on the surface. In conclusion, the usage of vacuum cleaners may contribute to more particulate matter being released inside the air due to the resuspension phenomenon. Therefore, it is important for the occupants to maintain proper ventilation after each vacuuming activities took place.
References
Adhikari, R., D’Souza, J., Soliman, EZ, Burke, G. L., Daviglus, M. L., Jacobs, D.R., Park, S.K…..Adar, S.D. (2016). Long-term Coarse Particulate Matter Exposure and Heart Rate Variability in the Multi-ethnic Study of Atherosclerosis. Epidemiology, 27(3), 405–413. DOI: https://doi.org/10.1097/EDE.0000000000000455
Afshari A, Matson U., & Ekberg LE. (2005). Characterization of indoor sources of fine and ultrafine particles: A study conducted in a full-scale chamber. Indoor Air, 15(2), 141-50. DOI: https://doi.org/10.1111/j.1600-0668.2005.00332.x
Brown, J. S., Gordon, T., Price, O., & Asgharian, B. (2013). Thoracic and respirable particle definitions for human health risk assessment. Particle and Fibre Toxicology, 10(12), 51-60 DOI: https://doi.org/10.1186/1743-8977-10-12
Corsi R. L., Siegel, J. A., & Chiang, C. (2008). Particle Resuspension during the Use of Vacuum Cleaners on Residential Carpet. Journal Occupational Environment Hygiene, 5(1), 232-238. DOI: https://doi.org/10.1080/15459620801901165
Ferro, A. R., Kopperud, R. J., & Hildemann, L. (2004). Elevated personal exposure to particulate matter from human activities in a residence. Journal Exposure Analysis and Environment Epidemiology, 14(1), 34-40. DOI: https://doi.org/10.1038/sj.jea.7500356
Frankel, M., Timm, M., Hansen E.W., & Madsen A. M. (2012), Comparison of sampling methods for the assessment of indoor microbial exposure. Indoor Air, 22, 405–414. DOI: https://doi.org/10.1111/j.1600-0668.2012.00770.x
Goldasteh, I., Ahmadi, G., & Ferro, A. (2011). Particle Resuspension from Carpeted Floorings in Indoor Environment In Turbulent Flows. Proceedings of the ASME 2011, International Mechanical Engineering Congress & Exposition IMECE 2011. November 11-17th, Denver, Colorado. DOI: https://doi.org/10.1115/IMECE2011-65054
Jimoda, L. A (2012). Effects of particulate matter on human health, the ecosystem, climate and materials: A review. Working and Living Environmental Protection, 9(1), 27-44. Retrieved from http://facta.junis.ni.ac.rs/walep/walep201201/walep201201-04.pdf
Klepeis, N.E, Nelson, W.C., Ott, W.R., Robinson J.P., Tsang A.M., Switzer, P., Behar, J.V….. Engelmann, W.H. (2001). The National Human Activity Pattern Survey (Nhaps): A Resource for Assessing Exposure to Environmental Pollutants. J Expo Anal Environ Epidemiol, 11(3), 231-52. DOI: https://doi.org/10.1038/sj.jea.7500165
Knibbs, L.D., He, C., Duchaine, C., & Morawska, L. (2012). Vacuum Cleaner Emissions as a source of indoor exposure to airbone particles and bacteria. Environment. Science.Technology, 46, 534-542. DOI: https://doi.org/10.1021/es202946w
Lewis, R. D., Ong, K. H., Emo, B., Kennedy, J., Kesavan, J., & Elliot, M. (2018). Resuspension of house dust and allergens during walking and vacuum cleaning. Journal of Occupational and Environmental Hygiene, 15(3), 235-245 DOI: https://doi.org/10.1080/15459624.2017.1415438
Morgan, W. K. C. (1978). Industrial Bronchitis. British Journal of Industrial Medicine, 35, 285-291 DOI: https://doi.org/10.1136/oem.35.4.285
Mukai, C., Siegel, J.A, & Novoselac, A. (2009) Impact of Airflow Characteristics on Particle Resuspension from Indoor Surfaces. Aerosol Science and Technology, 43(10), 1022-1032, DOI: https://doi.org/10.1080/02786820903131073
Noto, H.P., Nordby, K., & Eduard, W. (2016). Relationships between Personal Measurements of ‘Total’ Dust, Respirable, Thoracic, and Inhalable Aerosol Fractions in the Cement Production Industry Ann. Occup. Hyg., 60(4), 453–466. DOI: https://doi.org/10.1093/annhyg/mev093
Oberoi, R.C , Choi, J. L. , Edwards, J.R. , Rosati, J. A., Thornburg, J., & Rodes, C.E. (2010) Human-Induced Particle Re-Suspension in a Room, Aerosol Science and Technology, 44(3), 216-229 DOI: https://doi.org/10.1080/02786820903530852
Oomen, A. G., & Lijzen., J.P.A. (2004). Relevancy of Human Exposure via House Dust to the Contaminants Lead & Asbestos, RIVM Report 711701037, Retrieved from https://pdfs.semanticscholar.org/7228/3d2bc2e3764256c1aa45c5a5d784f94e24f4.pdf
Qian, J., Ferro, A. R., & Fowler. K.R. (2008). Estimating the resuspension rate and residence time of indoor particles. Journal of the Air & Waste Management Association, 58(4), 502-516. DOI: https://doi.org/10.3155/1047-3289.58.4.502
Qian, J., Peccia, J., & Ferro, A. R. (2014). Walking-induced particle resuspension in indoor environments. Atmospheric Environment, 89, 464-481 DOI: https://doi.org/10.1016/j.atmosenv.2014.02.035
Rosati, J.A, Thornburg, J., & Charles, R. (2008). Resuspension of particulate matter from carpet due to human activity Journal Aerosol Science and Technology, 42, 472-482. DOI: https://doi.org/10.1080/02786820802187069
Tetre, L., Medina, S., Samoli, S.E. (2002). Short-term effects of particulate air pollution on cardiovascular diseases in eight European cities, Journal Epidemiology and community Health, 56, 773-779. DOI: https://doi.org/10.1136/jech.56.10.773
Thatcher., T. L., & Layton., D.W. (1995). Deposition, resuspension and penetration of particles within a residence. Atmospheric Environment, 29(13), 1487-1497. DOI: https://doi.org/10.1016/1352-2310(95)00016-R
US EPA (2007). Resuspension and Tracking of Particulate Matter from Carpet Due To Human Activity. Final Report. Retrieved online from https://cfpub.epa.gov/si/si_public_file_download.cfm?p_download_id=499465&Lab=NHSRC
White., K., & Dingle., P. (2002) The Effect of intensive Vacuuming on Indoor PM Mass Concentration, Proceedings: Indoor Air 2002. Retrieved from https://www.irbnet.de/daten/iconda/CIB7044.pdf
World Health Organisation. (1999). Hazard Prevention and Control in the Work Environment: Airborne Dust. Retrieved from https://www.who.int/occupational_health/publications/airdust/en/
Wu, C.L. & Wan, M. P., Chan, T.C., & Chao, C. (2012). Ultrafine particle resuspension during vacuum cleaning in a household environment. 10th International Conference on Healthy Buildings 2:1002-1007. Retrieved online http://repository.ust.hk/ir/bitstream/1783.1-56151/1/611310-ConfP-
-fulltext-pre.pdf
Ocak, Y., Kilicvuran, A., Eren, A. B., Sofuoglu, A., & Sofuoglu, S. C. (2012). Exposure to particulate matter in a mosque. Journal Atmospheric Environment, 56,169-176. DOI: https://doi.org/10.1016/j.atmosenv.2012.04.007